Jiayu Zhizun Home Micro Incubator - Complete Guide
1. Overview
• Automatic temperature and humidity control
• Intelligent LED color display with touch keys
• Dual Power: Supports AC 220V and DC 12V battery backup
• Automatic egg turning and countdown timers
2. Technical Data
• Temp Range: 0 to 99.9°C (Accuracy: ±0.1°C)
• Humidity Range: 0-99% RH (Accuracy: ±2% RH)
• Egg Turning Cycle: Adjustable 0-999 minutes (Default: 90 min)
• Egg Turning Duration: Adjustable 0-999 seconds (Default: 26 sec)
• Environment: Temperature 10°C to 35°C, Humidity < 85% RH
• Humidity Range: 0-99% RH (Accuracy: ±2% RH)
• Egg Turning Cycle: Adjustable 0-999 minutes (Default: 90 min)
• Egg Turning Duration: Adjustable 0-999 seconds (Default: 26 sec)
• Environment: Temperature 10°C to 35°C, Humidity < 85% RH
3. Incubation Schedules
Chicken Incubation
| Period | Temp (°C) | Humidity | Egg Turning |
|---|---|---|---|
| Days 1-7 | 38.0 | 60% | Every 90 min |
| Days 8-14 | 37.8 | 60% | Every 90 min |
| Days 15-18 | 37.7 | 60% | Every 90 min |
| Days 19-21 | 37.5 | 65% | STOP turning |
Duck Incubation
| Period | Temp (°C) | Humidity | Notes |
|---|---|---|---|
| Days 1-3 | 38.2 | 60% | Turning active |
| Days 4-25 | 37.8 - 37.5 | 60-65% | Turning active |
| Days 26-28 | 37.2 | 75% | STOP turning |
Goose Incubation
| Period | Temp (°C) | Humidity | Notes |
|---|---|---|---|
| Days 1-3 | 38.3 | 60% | Turning active |
| Days 4-25 | 37.8 - 37.5 | 65% | Turning active |
| Days 26-30 | 37.2 | 70% | STOP turning |
Pigeon Incubation
| Period | Temp (°C) | Humidity | Notes |
|---|---|---|---|
| Days 1-13 | 38.2 - 37.8 | 60% | Turning active |
| Days 14-17 | 37.5 | 65% | STOP turning |
4. Controller Operation
• Mode Switching: Hold the 'Mode' key for 5 seconds to select species.
• Manual Egg Turn: Press the '+' key once to rotate rollers manually.
• Factory Reset: Hold '+' and '-' keys together until the screen resets.
• Egg Candler: Press the 'illuminating' key to activate the built-in light.
• Stop Auto-Turn: Hold 'Stop Eggs Turning' for 5 seconds to toggle off.
• Manual Egg Turn: Press the '+' key once to rotate rollers manually.
• Factory Reset: Hold '+' and '-' keys together until the screen resets.
• Egg Candler: Press the 'illuminating' key to activate the built-in light.
• Stop Auto-Turn: Hold 'Stop Eggs Turning' for 5 seconds to toggle off.
5. Advanced Configuration (Internal Codes)
Access these by holding 'Set' and '+' together:
• P1: High temperature alarm trigger (Factory: 38.5°C)
• P2: Heating stop value (Factory: 37.8°C)
• P3: Heating start value (Factory: 37.6°C)
• P4: Low temperature alarm trigger (Factory: 36.8°C)
• H1: High humidity alarm (Factory: 85% RH)
• H2: Low humidity alarm (Factory: 30% RH)
• F1: Egg turning cycle interval (Factory: 90 min)
• F2: Egg turning duration (Factory: 26 sec)
• F3: Temperature calibration offset (Used for synchronization)
• P2: Heating stop value (Factory: 37.8°C)
• P3: Heating start value (Factory: 37.6°C)
• P4: Low temperature alarm trigger (Factory: 36.8°C)
• H1: High humidity alarm (Factory: 85% RH)
• H2: Low humidity alarm (Factory: 30% RH)
• F1: Egg turning cycle interval (Factory: 90 min)
• F2: Egg turning duration (Factory: 26 sec)
• F3: Temperature calibration offset (Used for synchronization)
How to enter F state (according to the manual)
Power on the incubator normally.
Press and hold the SET key for about 3–5 seconds
– the display changes from the normal temperature screen to F1 / F parameters.
You are now in F state.
Use ▲ / ▼ to scroll between parameters (F1, F2, F3, etc.).
Press SET briefly to edit a parameter.
Use ▲ / ▼ to change the value.
Press SET again to save.
Wait a few seconds without pressing any key (or power-cycle) to exit F state and return to normal operation.
Important notes from the manual
Do not change factory parameters unless necessary – wrong values can affect temperature control and hatching results.
Some F parameters are calibration or protection values and should only be adjusted if you know the correct setting.
Power on the incubator normally.
Press and hold the SET key for about 3–5 seconds
– the display changes from the normal temperature screen to F1 / F parameters.
You are now in F state.
Use ▲ / ▼ to scroll between parameters (F1, F2, F3, etc.).
Press SET briefly to edit a parameter.
Use ▲ / ▼ to change the value.
Press SET again to save.
Wait a few seconds without pressing any key (or power-cycle) to exit F state and return to normal operation.
Important notes from the manual
Do not change factory parameters unless necessary – wrong values can affect temperature control and hatching results.
Some F parameters are calibration or protection values and should only be adjusted if you know the correct setting.
6. Troubleshooting (Error Codes)
• EEE: Temperature sensor fault or disconnection.
• EEH: Humidity sensor fault or disconnection.
• Alarms: If the buzzer sounds, check if water is empty or the lid is open.
• EEH: Humidity sensor fault or disconnection.
• Alarms: If the buzzer sounds, check if water is empty or the lid is open.
Usage Tip: For optimal stability, keep the incubator inside the white foam shipping box during winter or in cold rooms (below 15°C).